Design standards manual city of bloomington, indiana. Bureau of engineering manual part f sewer design 692 f 200 f 200 introduction section f 200 provides city standards, policy and procedures for the hydraulic design of sewers. Design and construction standards index january 2012 design and construction standards volume 3 drainage chapter 3 design standards for detailed list of contents refer to the front of chapter 3. Aisis transportation and infrastructure group develops specifications, design guides and innovative engineering solutions to make steel the material of. Together with the esld this document details all the information required as well as design and construction standards to. Part f of the manual covers bureau of engineering sewer design. The purpose of this design standards manual is to establish uniformity and consistency in engineered water and wastewater facility designs. Sewer systems including pumping stations integral to gravity sewer and lowpressure sewer designs require ownership by a responsible party, such as a public entity, for operation and maintenance. The following requirements establish the standards and procedures that apply to the design, construction, and connection to sanitary sewer collection systems located within the boundar ies of the metropolitan sewer subdistrict metro or systems to be incorporated into metros collection system. The design and construction of wastewater mains and other appurtenances within camrosa water district shall comply with these standards herein called, sanitary sewer design and construction standards and the permit requirements of various governing bodies. Rogue valley sewer services design standards 7 page of 14 3. Storm sewer design involves estimation runoff from an area design of the sewer and other hydraulics structures in the drainage system.
Effective jul 1, year june 30 year of each 2 year period. Sanitary sewer system design and construction standards. The following design standards, or their latest versions, are to be adopted, except. General the purpose of this document is to provide requirements to contractors for any project requiring sanitary sewer and septic system design and construction. Sanitary sewer mains shall be of adequate size to convey population generated peak dry weather flows, plus a general allowance for inflow and. Included herein are design standards, submittal policy, construction requirements, inspection, acceptance procedures, and other pertinent information relating to extensions andor replacements to the water andor sanitary sewer system. This design standards manual has been developed for use by engineers, consultants and developers working on water, sanitary, and stormwater utility projects within the city of bloomington utilities cbu jurisdiction in bloomington, indiana. Situations that would require calculations are pipe size increases to accommodate larger current or future. Otherwise, all documents should be prepared in pdf format. With good intent, this reduces the potential for maintenance difficulties associated with deep sewers.
Design and construction standards volume 3 drainage posted to the city of edmontons website in may 2012. The design of carrying capacities of lateral, trunk, and interceptor sewers shall be based upon the total sewer shed area served by the line or lines in question. These standards and drainage service guidelines are designed for 2 different types of sewers, sanitary and storm. In streets which meander in each direction, the sewer line will conform to the above specifications as near as is practical, but shall not zigzag across the street centerline. Specifications and details for the design and construction. The design standards and guidelines dsg include engineering requirements, details, specifications, policies, and procedures. The american iron and steel institute actively promotes the use of steel in construction. Sanitary sewer system design br constructlon manual. Sanitary sewer design standards revised august 2008 7 of 16 sanitary sewer pipes shall run in a straight alignment and no curved or deflected pipes shall be permitted. The attached domestic wastewater facilities manual has been prepared as a guide for persons. Second edition 032016 page 1 design standards manual chapter 1 general requirements 1.
The district maintains a manual of minimum construction standards and technical specifications to provide clear guidance regarding the minimum construction standards for design and construction work associated with wastewater systems within the district. Penndot preeps submission checklist autocad standards. A copy of the 20 standards can be found by downloading the manual. Publication of the addendum to the design and construction standards for wastewater. Volume i contains the design standard for water mains, pump stations and sewer lines, force. It is expected engineers will bring to each project the best of skills from their respective disciplines. Standard sewer specifications and details material specifications for sanitary sewer construction unless superseded or modified by a special provision, all materials, apparatus, supplies, methods of manufacture, or construction shall conform to. The new performance standard is intended to reduce peak discharges to the citys sewer system during rain events by requiring greater onsite storage of stormwater runoff and slower release to the sewer system. Minimum standards for design and construction of onsite wastewater systems fulfills that purpose. Standards and specifications manual city of richmond hill. The sewer design guide is a guide for the engineer when planning and designing. The criteria are adopted to encourage consistency in the development of sanitary sewer systems in the city and county of denver.
The design flow shall be based on acreage density, using these standards and the dpu water and sewer facilities plan. All previous department of public works criteria for sanitary sewer design are hereby superseded. Sewer design guide sewer design guide preface 20 preface the sewer design guide is a guide for the engineer when planning and designing wastewater facilities and should be used for both public facilities and private facilities which serve multiple lots. Sanitary sewer design standards amazon web services. However, if sewers constructed at depths greater than 20 feet eliminate the need for a sewage pumping station the extra depth maybe allowed. Design criteria sanitary sewers service connections. The department approval or issuance of permit does not, in any way, relieve the design. Design and construction standards for wastewater collection. Mf2214 minimum standards for design and construction of. The dsg help spu design engineers, project managers, and consultants perform engineering work for spu. These standards are to be used by design professionals for design work, and construction. The district realizes that there are occasions when extenuating circumstances occur, and these standards will not work in all situations.
Design calculations are required where a simple 8 diameter gravity sewer is inadequate to serve the current or future project area. The minimum standards presented in this document are intended to ensure domestic wastewater is managed so that. Guidelines for the design and construction of stormwater. It provides guidelines for the projections of residential, commercial and industrial wastewater flows. Introduction this course provides standards, policy, and procedures for the hydraulic design of sanitary gravity sewer systems based on rules and regulations in the state of florida including specific regulations within the miamidade county. Approximate sewer main sizes to serve the number of edus. Effluent disposal is typically provided by leach fields, absorption beds, leaching chambers, or seepage pits. These criteria, standards, policies and procedures are intended as guidelines. These standards have been adopted by the district and shall be incorporated into the design of all sanitary sewer system design and construction.
It presents the design criteria, standards, policies, and procedures to the new engineer and provides a reference source for the experienced engineer. Generally, sewer outfalls and trunk mains shall be sized for the future full development of the basin using the following criteria unless more specific data is available. City and guilds or sqa standard or cabwi level 2 award certificate for working in medium or high risk. The 20 manual will only apply to submissions received by spotsylvania county on or before october 23, 2018. The size of mainline sewer pipe shall be determined by standards of design and the coefficients determined by the city engineer, but in no case shall it. The design criteria in these standards are intended for the more conventional municipal wastewater collection and treatment systems. The standards are not intendedas a regulation but should be used as a guide which will establish a degree of uniformity for drawings and specifications for all water and sewer utility projects. Design criteria shall be included with all plans and specifications and a hydraulic profile shall be included for all wastewater treatment facilities. Design submittals shall not include flow from rainwater, storm sewers, streets or. Standards for water and sewer design and construction page 5 of 10 if accepted for ownership and maintenance the system must meet current design and construction standards of the jwsc or the standards of the city of brunswick or glynn county at the time of installation and the system must be functioning properly.
Developers wishing to deviate from the standards are to. The following procedures and crit eria are to be used for sizing and hydraulic design of gravity sanitary sewers. Modern sewer design are encouraged to offer suggestions for improvements in future editions. This guide summarizes and outlines relevant city policies. For new pipe materials for which astm standards have not been established.